Filter by:

Clear All

Flat roof

View as Grid List
Sort by

EJOT Dabo® TKR-4.8

Applications :
For fixing roofing membrane to sheet steel substructures ≥ 0,75 mm ≤ 1 mm For timber substructures   In combination with EJOT® HTK 50 stress plate EJOT® HTV 82/40 TK stress plate EJOT® stress plate HTV 82/40 F EJOT® stress plate HTV 40 RU        

Properties :
Case-hardened steel Climadur coated - high-quality coating to improve corrosion protection (15 Kesternich cycles, DIN 50018, 1997) Can be delivered belted for EJOT® ECOset installation tool or pre-assembled with EJOT® stress plates HTK for EJOT® ECOset HTK installation tool.        

Technical specifications :
Drill capacity tI + tII: 2.0 mm Drive: H2 cross recess Length determination for: Sheet steel: insulation thickness +20 mm Timber: insulation thickness +30 mm * Min. lengths        

More information on : www.ejot.de

EJOT® tube washer HTK 2G

Applications :
To secure roofing membrane to substructures made of trapezoidal steel profiles, timber and wood-based materials For new buildings and renovations For special requirements of resistance to imposed loads Limits cold bridging For installation with EJOT® ECOset tools        

Properties :
High-grade plastic material Telescope design for resistance to imposed loads Available loosely pre-assembled or collated        

Technical specifications :
For combination with EJOT roof drilling screws Dabo® TKR-4.8, Dabo® TKE-4.8 or Dabo® VHT-R-4.8        

More information on : www.ejot.de

EJOT® Flat roofing anchor FDD-Plus-50

Applications :
To fix roofing membrane Ideal for pitched roof insulation For concrete, lightweight concrete and aerated concrete substructures Limits cold bridging        

Properties :
Anchor sleeve made of high-grade plastic material Anchor screw made of A2 stainless steel or steel, high-quality organic coating (15 Kesternich cycles, DIN 50018, 1997); Cr(VI) free        

Technical specifications :
Drill hole diameter: 8 mm Anchor screw drive: hexalobular/TORX® T30 Installation depth Concrete C12/15 ≥ 30mm Lightweight concrete LC12/13 ≥ 30mm Aerated concrete P 3.3 ≥ 65mm Drill hole depth Concrete C12/15 ≥ 45mm Lightweight concrete LC12/13 ≥ 45mm Aerated concrete P 3.3 ≥ 80mm        

More information on : www.ejot.de

EJOT® FBS-R-6.3

Applications :
To fix roofing membrane to concrete substructures In combination with EJOT® stress plates/tube washers        

Properties :
Case-hardened steel Climadur coated-high-quality coating to improve corrosion protection (15 Kesternich cycles, DIN 50018, 1997)        

Technical specifications :
Drive: hexalobular / TORX® T30 Embedment depth: ≥ 30 mm Hole depth: ≥ 45 mm Drill nominal diameter: 5.0 mm        

More information on : www.ejot.de

EJOT® HTV 82/40 F

Applications :
To fix roofing membrane to substructures made of timber, wood-based materials, concrete and aerated concrete For solid substrate Note For combination with all EJOT Dabo® screws / with concrete and aerated concrete screws        

Properties :
Alu-zinc coated steel        

Technical specifications :
See further products for compatibility For dimensions of plate see downloads        

More information on : www.ejot.de

EJOT® HTV RU

Applications :
To fix roofing membrane and to fasten pressure-resistant insulation to substructures made of trapezoidal steel profiles, timber, wood-based mmaterials, concrete and aerated concrete Note Compatible with EJOT Dabo® screws / with concrete and aerated concrete screws        

Properties :
Alu-zinc coated steel        

Technical specifications :
See further products for compatibility For dimensions of plate see downloads        

More information on : www.ejot.de

EJOT® tube washer EcoTek 50

Applications :
To fix roofing membrane For special requirements of resistance to imposed loads Limits cold bridging Note   For combination with EJOT® Dabo screws / with concrete and aerated concrete screws          

Properties :
High-grade plastic material In combination for insulation material thicknesses up to 595 mm (FBS-R) and up to 600 mm (TKR) Telescope design, prevents screw head protrusion due to foot traffic even with soft insulating material        

Technical specifications :
For combination with gas concrete screw FPS-E-8.0 and concrete screw FBS-R-6.3        

More information on : www.ejot.de

EJOT® HTV 82/40 TK

Applications :
To fix roofing membrane to substructures made of trapezoidal steel profiles, timber and wood-based materials For new buildings und renovations For installation with EJOT® ECOset tools For manual installation For combination with EJOT Dabo® screws TKR, TKE and VHT-R        

Properties :
Alu-zinc coated steel        

Technical specifications :
Used with TKR and TKE fasteners For dimensions of plate see downloads        

More information on : www.ejot.de

EJOT® HTV 82/40

Applications :
To fix roofing membrane to substructures made of trapezoidal steel profiles, timber and wood-based materials For new buildings and renovations For installation with EJOT® ECOset tools For manual installation For combination with EJOT Dabo® screw SW 8 RT        

Properties :
Alu-zinc coated steel        

Technical specifications :
Used with SW8R and TKR fasteners For dimensions of plate see downloads        

More information on : www.ejot.de

EJOT Dabo® TKE-4.8

Applications :
To fix roofing membrane to substructures made of sheet steel ≥ 0.75 mm ≤ 1.5 mm, timber and wood-based material For renovations For combination with EJOT® stress plates/tube washers        

Properties :
A4 stainless steel with hardened drill point Can be delivered belted for EJOT® ECOset installation tool or pre-assembled with HTK for EJOT® ECOset HTK.        

Technical specifications :
Drill capacity tI + tII: 1.5 mm Drive: H2 cross recess Length determination (min. lengths) Sheet steel: Insulation thickness + 20 mm Timber: Insulation thickness + 30 mm        

More information on : www.ejot.de

EJOT Dabo® SW8 RT-4.8

Applications :
To secure roofing membrane to sheet steel substructures ≥ 0.75 mm ≤ 1 mm For special requirements of resistance to imposed loads In combination with EJOT® stress plate HTV 82/40 For timber substructures        

Properties :
Case-hardened steel Climadur coated - high-quality coating to improve corrosion protection (15 Kesternich cycles, DIN 50018, 1997)        

Technical specifications :
Drilling capacity tI + tII: 1.5 mm A/F8 hexagon drive Length determination for: Sheet steel: insulation thickness +20 mm Timber: insulation thickness +30 mm * Min. lengths        

More information on : www.ejot.de

EJOT® SAPHIR self-drilling screw JT2-6-6.3

Applications :
Fastening profiled steel sheet to 2–5 mm steel substructure        

Properties :
Case-hardened steel, zinc-plated Steel sealing washer, zinc-plated Pre-assembled sealing washer        

Technical specifications :
Drilling capacity tI + tII: 1.5 + 5.0 mm Drive: Hexagon AF 3/8" Max. tightening torque (screws without sealing washer): 7.0 Nm        

More information on : www.ejot.de

EJOT® SUPER-SAPHIR self-drilling screw JT3-2-6.5

Applications :
Fastening profiled steel and aluminium sheet, sandwich panels and roofing sheet to timber substructure        

Properties :
A2 stainless steel with hardened drill point Stainless steel sealing washer Pre-assembled sealing washer        

Technical specifications :
Drilling capacity tI + tII: 2.0 mm Drive: Hexagon AF8 Ø screw: 6.5 mm        

More information on : www.ejot.de

EJOT® FPS-E-8.0

Applications :
To fix roofing membrane to aerated concrete substructures In combination with EJOT® stress plates/tube washers        

Properties :
A4 stainless steel Approved for P3.3 aerated concrete onwards No pre-drilling        

Technical specifications :
Drive: hexalobular / TORX® T30 Embedment depth ≥ 60 mm        

More information on : www.ejot.de

EJOT® tube washer HTK-2G collated

Applications :
To secure roofing membrane to substructures made of trapezoidal steel profiles, wood and wood-based material For new buildings and renovations For installation with EJOT® ECOset HTK installation tool For special requirements of resistance to imposed loads Limits cold bridging Note For combination with EJOT Dabo® screws Drill capacity = 3 mm on request!        

Properties :
Dabo® screw TKR = Case-hardened steel, Climadur* coated Dabo® screw TKE = A4 stainless steel collated Telescope design for resistance to imposed loads Combinations for insulation thicknesses up to 600 mm on request *Climadur High-grade coating to improve the corrosion protection (15 Kesternich cycles, DIN 50018, 1997)        

Technical specifications :
Drilling capacity (TKR/TKE): 1.50 mm Drilling capacity (VHT-R): 0.75 mm Collator capacity: 25 pcs.        

More information on : www.ejot.de

EJOT Dabo® SW8 RT-4.8 belted

Applications :
To secure roofing membrane to sheet steel substructures ≥ 0.75 mm ≤ 1 mm For special requirements of resistance to imposed loads In combination with EJOT® stress plate HTV 82/40 For timber substructures        

Properties :
Case-hardened steel Climadur coated - high-quality coating to improve corrosion protection (15 Kesternich cycles, DIN 50018, 1997)        

Technical specifications :
Drill capacity tI + tII: 2.0 mm A/F8 hexagon drive Length determination for: Sheet steel: insulation thickness +20 mm Timber: insulation thickness +30 mm * Min. lengths        

More information on : www.ejot.de

EJOT Dabo® VHT-R-4.8

Applications :
To fix roofing membrane to substructures made of sheet steel ≥ 0.5 mm ≤ 0.75 mm, timber and wood-based material In combination with EJOT® HTK 50 stress plate EJOT® HTV 82/40 TK stress plate EJOT® stress plate HTV 82/40 F EJOT® stress plate HTV 40 RU Note For thicker and/or two-ply sheet steel we recommend use of the EJOT Dabo® screw TKR-4.8        

Properties :
Case-hardened steel Climadur coated - high-quality coating to improve corrosion protection (15 Kesternich cycles, DIN 50018, 1997)        

Technical specifications :
Drilling capacity: 0.75 mm Drive: H2 cross recess        

More information on : www.ejot.de