Filter by:
Clear AllApplications :
To secure roofing membrane to substructures made of trapezoidal steel profiles, timber and wood-based materials
For new buildings and renovations
For special requirements of resistance to imposed loads
Limits cold bridging
For installation with EJOT® ECOset tools
Properties :
High-grade plastic material
Telescope design for resistance to imposed loads
Available loosely pre-assembled or collated
Technical specifications :
For combination with EJOT roof drilling screws Dabo® TKR-4.8, Dabo® TKE-4.8 or Dabo® VHT-R-4.8
More information on : www.ejot.de
Applications :
To fix roofing membrane
Ideal for pitched roof insulation
For concrete, lightweight concrete and aerated concrete substructures
Limits cold bridging
Properties :
Anchor sleeve made of high-grade plastic material
Anchor screw made of A2 stainless steel or steel, high-quality organic coating (15 Kesternich cycles, DIN 50018, 1997); Cr(VI) free
Technical specifications :
Drill hole diameter: 8 mm
Anchor screw drive: hexalobular/TORX® T30
Installation depth
Concrete C12/15 ≥ 30mm
Lightweight concrete LC12/13 ≥ 30mm
Aerated concrete P 3.3 ≥ 65mm
Drill hole depth
Concrete C12/15 ≥ 45mm
Lightweight concrete LC12/13 ≥ 45mm
Aerated concrete P 3.3 ≥ 80mm
More information on : www.ejot.de
Applications :
To fix roofing membrane to substructures made of timber, wood-based materials, concrete and aerated concrete
For solid substrate
Note
For combination with all EJOT Dabo® screws / with concrete and aerated concrete screws
Properties :
Alu-zinc coated steel
Technical specifications :
See further products for compatibility
For dimensions of plate see downloads
More information on : www.ejot.de
Applications :
To fix roofing membrane and to fasten pressure-resistant insulation to substructures made of trapezoidal steel profiles, timber, wood-based mmaterials, concrete and aerated concrete
Note
Compatible with EJOT Dabo® screws / with concrete and aerated concrete screws
Properties :
Alu-zinc coated steel
Technical specifications :
See further products for compatibility
For dimensions of plate see downloads
More information on : www.ejot.de
Applications :
To fix roofing membrane
For special requirements of resistance to imposed loads
Limits cold bridging
Note
For combination with EJOT® Dabo screws / with concrete and aerated concrete screws
Properties :
High-grade plastic material
In combination for insulation material thicknesses up to 595 mm (FBS-R) and up to 600 mm (TKR)
Telescope design, prevents screw head protrusion due to foot traffic even with soft insulating material
Technical specifications :
For combination with gas concrete screw FPS-E-8.0 and concrete screw FBS-R-6.3
More information on : www.ejot.de
Applications :
To fix roofing membrane to substructures made of trapezoidal steel profiles, timber and wood-based materials
For new buildings und renovations
For installation with EJOT® ECOset tools
For manual installation
For combination with EJOT Dabo® screws TKR, TKE and VHT-R
Properties :
Alu-zinc coated steel
Technical specifications :
Used with TKR and TKE fasteners
For dimensions of plate see downloads
More information on : www.ejot.de
Applications :
To fix roofing membrane to substructures made of trapezoidal steel profiles, timber and wood-based materials
For new buildings and renovations
For installation with EJOT® ECOset tools
For manual installation
For combination with EJOT Dabo® screw SW 8 RT
Properties :
Alu-zinc coated steel
Technical specifications :
Used with SW8R and TKR fasteners
For dimensions of plate see downloads
More information on : www.ejot.de
Applications :
For the structural fixation of insulations to substructures made of trapezoidal steel profiles, timber and wood-based materials
For new buidlings and renovation (cf. current Flat Roof Guideline)
For special requirements of resistance to imposed loads
To reduce thermal bridges
Properties :
High-grade plastic material
Telescope design for resistance to imposed loads
For insulating material thicknesses up to 425 mm
Loosely pre-assembled
Note
For combination with EJOT Dabo® screws
More information on : www.ejot.de
Applications :
To secure roofing membrane to substructures made of trapezoidal steel profiles, wood and wood-based material
For new buildings and renovations
For installation with EJOT® ECOset HTK installation tool
For special requirements of resistance to imposed loads
Limits cold bridging
Note
For combination with EJOT Dabo® screws Drill capacity = 3 mm on request!
Properties :
Dabo® screw TKR = Case-hardened steel, Climadur* coated
Dabo® screw TKE = A4 stainless steel collated
Telescope design for resistance to imposed loads
Combinations for insulation thicknesses up to 600 mm on request
*Climadur
High-grade coating to improve the corrosion protection
(15 Kesternich cycles, DIN 50018, 1997)
Technical specifications :
Drilling capacity (TKR/TKE): 1.50 mm
Drilling capacity (VHT-R): 0.75 mm
Collator capacity: 25 pcs.
More information on : www.ejot.de