Applications :
Universal hammer-in anchor
Approved for all material classes (A, B, C, D, E)
For all insulation boards
For surface fixed installation
With European Technical Approval (ETA)
Properties :
Approved for concrete, solid and perforated masonry
Solid steel nail (break-proof)
Low profile washer face
Plastic injection element to reduce thermal transmission (0,001 W/K)
Can be used with an additional spreader washer
KShort embedment depth, reduced drilling
High loads for your security
Economic anchor usage
Premounted nail for quick installation
Technical specifications :
Anchor diameter: 8 mm
Washer diameter: 60 mm
Drill hole depth h1 ≥: 35 mm
Embedment depth hef≥: 25 mm
Point thermal transmission χ: 0.001 W/K
Use categories acc. to ETA: A, B, C
European Technical Approval: ETA-11/0192
Characteristic loads:
Building material class A:
Normal weight concrete C 12/15 acc. to EN 206-1: 0.9 kN
Normal weight concrete C 16/20 - C 50/60 acc. to EN 206-1: 0.9 kN
Building material class B:
Clay bricks (Mz) acc. to DIN 105: 0.9 kN
Solid lime sandstone (KS) acc. to DIN EN 106: 0.9 kN
Building material class C:
Vertically perforated clay brick (Hlz) acc. to DIN 105, bulk density ≥ 1.2 kg/dm3: 0.75 kN
Vertically perforated clay brick (Hlz) acc. to DIN 105, bulk density ≥ 0.9 kg/dm3: 0.6 kN
Sand-lime perforated (KSL) acc. to DIN EN 106: 0.9 kN
For calculation of design loads the national safety factors have to be included (e.g. Germany: 3). Please observe the approval.
More information on : www.ejot.de
Applications :
Universal screw-in anchor for countersunk and surface fixed installation in concrete and masonry
For all substrates (A, B, C, D, E)
For all insulation boards
For countersunk and surface fixed installation
For homogeneous surfaces and even rendering
Up to 40% faster installation
With European Technical Approval (ETA)
Properties :
Approved for all building materials
Countersunk installation - EJOT STR principle with ejotherm STR cap for homogeneous surfaces and even rendering - quick and easy without milling dust
Up to 40% fastener installation
Reduced thermal transmission (0.001 W/K)
Surface fixed installation using ejotherm STR plug
Short embedment depths, high loads for maximum safety and economic anchor usage
Permanent contact pressure
Premounted screw for quick installation
100% setting control: the countersunk installation of the washer indicates safe anchorage
Technical specifications :
Anchor diameter: 8 mm
Washer diameter: 60 mm
Drill hole depth, countersunk installation h1 ≥: 50 mm (90 mm)
Drill hole depth, surface fixed installation h2 ≥: 35 mm (75 mm)
Anchorage depth hef≥: 25 mm (65 mm)
Screw drive: TORX T30
Point thermal transmission χ
countersunk installation: 0,001 W/K
surface fixed installation: 0,002 W/K
Use categories acc. to ETA*: A, B, C, D, E
German DIBt approval: Z-21.2-1769
European Technical Approval: ETA-04/0023
Values in parentheses: anchoring in aerated concrete (use category E)
*Specification according to ÖNORM B 6124 for concrete, solid brick and vertical brick
Characteristic loads:
Building material class A:
Normal weight concrete C 12/15 acc. to EN 206-1: 1.5 kN
Normal weight concrete C 16/20 - C 50/60 acc. to EN 206-1: 1.5 kN
Pre-cast concrete panel C16/20 - C50/60: 1.5 kN
Building material class B:
Clay bricks (Mz) acc. to DIN 105: 1.5 kN
Solid lime sandstone (KS) acc. to DIN EN 106: 1.5 kN
Solid masonry of lightweight concrete (V) acc. to DIN 18152: 0.6 kN
Building material class C:
Vertically perforated clay bricks (Hlz) acc. to 105: 1.2 kN
Vertical coring reference bricks (Hlz) acc. to ÖNORM B 6124: 0.75 kN
Sand-lime perforated (KSL) acc. to EN 106: 1.5 kN
Lightweight concrete hollow blocks (HbL)acc. to DIN 18151: 0.6 kN
Baustoffklasse D:
Lightweight aggregate concrete (LAC): 0.9 kN
Building material class E:
Autoclaved aerated concrete P2 - P7: 0.75 kN
For calculation of design loads the national safety factors have to be included (e.g. Germany: 3). Please observe the approval.
More information on : www.ejot.de
Applications :
Universal hammer-in anchor
For concrete, solid and perforated masonry (A, B, C)
For all insulation boards
With European Technical Approval (ETA)
Properties :
Approved for concrete, solid and perforated masonry
Solid steel nail (break-proof)
Plastic injection moulding to reduce thermal transmission
Can be used with an additional spreader washer
Short embedment depths, reduced drilling
High loads for your security
Economic anchor usage
Premounted nail for quick installation
Technical specifications :
Anchor diameter: 8 mm
Washer diameter: 60 mm
Drill hole depth h1≥: 35 mm
Embedment depth hef≥: 25 mm
Point thermal transmission χ: 0.002 W/K
Use categories ETA: A, B, C
European Technical Approval: ETA-05/0009
Characteristic loads:
Building material class A:
Normal weight concrete C 12/15 acc. to EN 206-1: 1.2 kN
Normal weight concrete C 16/20 - C 50/60 acc. to EN 206-1: 1.2 kN
Building material class B:
Clay bricks(Mz) acc. to DIN 105: 1.5 kN
Solid lame sandstone (KS) acc. to DIN EN 106: 1.5 kN
Solid masonry of lightweight concrete (V) acc. to DIN 18152: 0.5 kN
Building material class C:
Vertically perforated clay bricks (Hlz) acc. to DIN 105: 0.9 kN
Sand-lime perforated bricks (KSL) acc. to DIN EN 106: 1.5 kN
Lightweight concrete hollow blocks (HbL) acc. to DIN 18151: 0.5 kN
More information on : www.ejot.de
Applications :
Universal hammer-in anchor
For concrete, solid and perforated masonry (A, B, C)
For all insulation boards
With European Technical Approval (ETA)
Properties :
Approved for concrete, solid and perforated masonry
Upon installation, the washer face de-couples from the sleeve, ensuring a flush finish with the insulation surface
Safe and smooth installation with built-in setting control through the EJOT telescope effect
Zero thermal transmission
Minimised risk of breaking nails due to fibre-reinforced composites
Premounted expansion nail for quick installation
Technical specifications :
Anchor diameter: 8 mm
Washer diameter: 60 mm
Drill hole depth h1 ≥: 50 mm
Embedment depth hef≥: 40 mm
Point thermal transmission χ: 0.000 W/K
Use categories ETA: A, B, C
German DIBt approval: Z-21.2-1844
European Technical Approval: ETA-07/0026
Characteristic loads:
Building material class A:
Normal weight concrete C 12/15 acc. to EN 206-1: 0.6 kN
Normal weight concrete C 16/20 - C 50/60 acc. to EN 206-1: 0.9 kN
Building material class B:
Clay bricks (Mz) acc. to DIN 105: 0.9 kN
Solid lame sandstone (KS) acc. to DIN EN 106: 0.9 kN
Building material class C:
Vertically perforated clay bricks (Hlz) acc. to DIN 105: 0.6 kN
Sand-lime perforated bricks (KSL) acc. to DIN EN 106: 0.9 kN
*For calculation of design loads the national safety factors have to be included (e.g. Germany: 3). Please observe the approval.
More information on : www.ejot.de
Applications :
ejotherm STR plug
Special polystyrene (EPS) isolation plug
To be used with ejotherm STR U 2G, ejotherm STR U for surface fixed installation
ejotherm STR plug is included in the packaging of ejotherm STR H
More information on : www.ejot.de
Applications :
ejotherm STR cap MW
Specially developed mineral wool insolation cap
For countersunk Installation acc. to EJOT STR principle
To be used with ejotherm STR U 2G, STR U, STR H, STR H A2 and ejotherm VT 2G
More information on : www.ejot.de
Applications :
ejotherm STR cap EPS
Specially developed polystrene (EPS) isolation cap
For coutnersunk Installation acc. to EJOT STR principle
To be used with ejotherm STR U 2G, ejotherm STR U,ejotherm STR H and STR H A2
Properties :
Colours: White and grey
More information on : www.ejot.de
Applications :
Used in conjunction with fasteners TKR, TKE and VHT-R
Properties :
Polyamide disc washer
Technical specifications :
60mm diameter
5mm inner diameter hole
More information on : www.ejot.de
Applications :
Screw fastener for countersunk and surface fixed installation
for timber and some steel substrates
For timber and steel (max. 0.75 mm) substrates
For all insulation boards
For countersunk and surface fixed installation
Properties :
Fastener, consistent of a galvanized steel screw, included washer and EPS sealing plug.
Countersunk Installation - EJOT STR principle with ejotherm STR cap for homogeneous surfaces and even rendering - quick and easy without milling dust
No drilling necessary
Surface fixed Installation using ejotherm STR plug
Permanent contact pressure
Premounted screw for quick installation
100% setting control: the countersunk Installation of the washer indicates safe anchorage
Technical specifications :
Screw diameter: 6 mm
Washer diameter: 60 mm
Screw-in depth: 30 - 40 mm
Screw drive: TORX T25
Point thermal transmission χ:
countersunk installation in timber substrates: 0.001 W/K
surface fixed installation in timber substrates: 0.002 W/K
Recommended use loads:
Wood fibreboards (thickness ≥ 17.0 mm): 0.25 kN
Chipboards (thickness ≥ 13.0 mm): 0.25 kN
Gypsum fibreboards (thickness ≥ 12.5 mm): 0.15 kN
OSB plates (thickness ≥ 16.0 mm): 0.25 kN
Solid wood plates (thickness ≥ 27.0 mm): 0.25 kN
The recommended use loads are calculated with a safety factor of 3. They may differ according to the object.
More information on : www.ejot.de
Applications :
Specifically for mineral wool lamella boards
Properties :
Washer diameter: 140 mm
The washer‘s high rigidity, allows for a equal compression across the face
High bearing loads once in contact with the render
Technical specifications :
Please note: When using additional washers VT90 and SBL 140 plus the EJOT STR principle cannot be applied.
More information on : www.ejot.de
Applications :
Load spreading disc washer for insulation
Properties :
Material: Polyamide
Technical specifications :
To be used in conjunction with EJOT anchors
90mm Diameter
More information on : www.ejot.de
Applications :
For surface fixed installation of ejotherm STR U 2G and ejotherm STR U: ejotherm STR bit TX30-M8 x 52
For countersunk installation of ejotherm STR H: ejotherm STR bit TX25-M8 x 31
More information on : www.ejot.de
Applications :
Specially developed tool for countersunk installation of ejotherm STR U 2G according to the EJOT STR principle Also compatible for use with ejotherm STR U und ejotherm STR H and STR H A2 For reliable and easy Installation according to the EJOT STR principle For all insulation boards
Properties :
Adjustment shaft with hex shank for easy use with standard drills Patented mechanism enables quick and easy adjustment to the required anchor length Easy conversion from ejotherm STR tool 2GS for surface fixed installation Robust design for long service life Worn parts can be changed quickly Set contains: ejotherm STR-tool 2GS, additional cutting discs, offset screw driver as well as bits for all applications
More information on : www.ejot.de
Applications :
Screw fastener for the corrosion resistant fixing of ETICS
with German DIBt approval
For Fermacell boards, cement particle boards, wooden substrates and metal Frame
For a corrsion-free fastening
For countersunk and surface fixed installation
For homogeneous surfaces
With German DIBt approval
Properties :
Fastener, consistent of a A2 stainless screw with hardened drill point, included washer and an EPS sealing plug
EJOT STR principle with ejotherm STR cap for homogeneous surfaces and even rendering - quick and easy without milling dust
Countersunk installation in mineral wool insulation boards WAP-zg (type WV) in combination with ejotherm VT 2G
No drilling necassary
Surface fixed installation with ejotherm STR plug
Permanent contact pressure
100% Setting control: the countersunk installation of the washer indicates safe anchorage
Technical specifications :
Screw diameter: 6 mm
Washer diameter: 60 mm
Screw-in depth: 30 - 40 mm
Screw drive: TORX T25
Point thermal transmission χ:
countersunk installation in timber substrates: 0.001 W/K
surface fixed installation in timber substrates: 0.002 W/K
German DIBt approval: Z-9.1-822
Tensile strength from the substrate:
Solid wood, laminated timber,laminated beams or cross laminated timber made of softwood
Minimum screw-in depth: 35 mm oder 24 mm (embedment)
Designed load Fax,90,Rd: 0.94kN
OSB boards
Minimum screw-in depth: 15 mm (thread engagement)
Designed load Fax,90,Rd: 0.56kN
Synthetic resin bonded chipboard
Minimum screw-in depth: 16 mm (thread engagement)
Designed load Fax,90,Rd: 0.56kN
Cement particle board
Minimum embedment depth: 16 mm (thread engagement)
Designed load Fax,90,Rd: 0.56kN
Detailed information about the substrates can be found in the German DIBt approval.
Die The options for structural fastening can be found in the technical data sheet.
More information on : www.ejot.de
Anwendungen :
Verstellschaft SDS-plus
Alternativer Verstellschaft mit SDS-plus Aufnahme für ejotherm STR-tool 2GS
Weitere Informationen unter: www.ejot.de
Applications :
Specifically matched combination washer for ejotherm STR U 2G for countersunk installation into all mineral wool insulation boards WAP-zg (type WV)
ejotherm VT 2G continues to promote the countersunk installation acc. to STR principle in all mineral wool insulation boards with a low tensil strength WAP-zg (type WV)
For homogeneous surfaces and even rendering
With European Technical Approval (ETA)
Properties :
Low point thermal transmission (Chi value 0.001 W/K)
Reduced anchor marks
No additional tool required
Permanent contact pressure
Anchor locates easily in the washer with a firm "click"
100% setting control
Technical specifications :
Washer diameter: 110 mm
German DIBt approval: Z-21.2-1769
European Technical Approval: ETA-04-0023
The quantity of anchors can be found in the mineral wool approvals for washers ≥90 mm..
More information on : www.ejot.de
Applications :
Used in conjunction with the SW8R and TKR to retain insulation to cement particle boards, timber and SFS upto 1.2mm thick
Properties :
Hole diameter: 5.2 mm
Washer diameter: 65 mm
Isolated washer with an integral cap
More information on : www.ejot.de
Applications :
Used in conjunction with fasteners and anchors depending of inner diameter
Properties :
Polyamide disc washer
Technical specifications :
60mm diameter
8mm inner diameter hole
More information on : www.ejot.de