Universal screw-in anchor for countersunk and surface fixed installation in concrete and masonry
For all substrates (A, B, C, D, E)
For all insulation boards
For countersunk and surface fixed installation
For homogeneous surfaces and even rendering
Up to 40% faster installation
With European Technical Approval (ETA)
Properties :
Approved for all building materials
Countersunk installation - EJOT STR principle with ejotherm STR cap for homogeneous surfaces and even rendering - quick and easy without milling dust
Up to 40% fastener installation
Reduced thermal transmission (0.001 W/K)
Surface fixed installation using ejotherm STR plug
Short embedment depths, high loads for maximum safety and economic anchor usage
Permanent contact pressure
Premounted screw for quick installation
100% setting control: the countersunk installation of the washer indicates safe anchorage
Technical specifications :
Anchor diameter: 8 mm
Washer diameter: 60 mm
Drill hole depth, countersunk installation h1 ≥: 50 mm (90 mm)
Drill hole depth, surface fixed installation h2 ≥: 35 mm (75 mm)
Anchorage depth hef≥: 25 mm (65 mm)
Screw drive: TORX T30
Point thermal transmission χ
countersunk installation: 0,001 W/K
surface fixed installation: 0,002 W/K
Use categories acc. to ETA*: A, B, C, D, E
German DIBt approval: Z-21.2-1769
European Technical Approval: ETA-04/0023
Values in parentheses: anchoring in aerated concrete (use category E)
*Specification according to ÖNORM B 6124 for concrete, solid brick and vertical brick
Characteristic loads:
Building material class A:
Normal weight concrete C 12/15 acc. to EN 206-1: 1.5 kN
Normal weight concrete C 16/20 - C 50/60 acc. to EN 206-1: 1.5 kN
Pre-cast concrete panel C16/20 - C50/60: 1.5 kN
Building material class B:
Clay bricks (Mz) acc. to DIN 105: 1.5 kN
Solid lime sandstone (KS) acc. to DIN EN 106: 1.5 kN
Solid masonry of lightweight concrete (V) acc. to DIN 18152: 0.6 kN
Building material class C:
Vertically perforated clay bricks (Hlz) acc. to 105: 1.2 kN
Vertical coring reference bricks (Hlz) acc. to ÖNORM B 6124: 0.75 kN
Sand-lime perforated (KSL) acc. to EN 106: 1.5 kN
Lightweight concrete hollow blocks (HbL)acc. to DIN 18151: 0.6 kN
Baustoffklasse D:
Lightweight aggregate concrete (LAC): 0.9 kN
Building material class E:
Autoclaved aerated concrete P2 - P7: 0.75 kN
For calculation of design loads the national safety factors have to be included (e.g. Germany: 3). Please observe the approval.
More information on : www.ejot.de
Applications :
Fastening of rail-systems
Screw-in anchor for rails
For fixing holding and base rails
Approved for all categories of building materials
Properties :
Approved for all categories of building materials
Shortest embedment depths, minimum drill hole depths
Highest loads for maximum safety
Economic anchor usage
Premounted screw for quick installation
To compensate facade tolerances use spacers EJOT AS
Technical specifications :
Anchor diameter: 8 mm
Collar diameter:16 mm
Drill hole depth h1 >: 35 mm (75 mm)
Embedment depth hef >: 25 mm (65 mm)
Screw drive: TORX T30
Use categories acc. to ETA: A, B, C, D
German DIBt approval: Z-21.2-1769
European Technical Approval: ETA-04/0023
Values in parentheses: anchoring in aerated concrete (use category E)
More information on : www.ejot.de
Applications :
Brick slip system anchor for concrete and masonry
For concrete, solid and perforated masonry
Anchor tube with small countersunk head for unobtrusive installation in the joint
Properties :
Approved for concrete, solid and perforated masonry (A, B, C, D)
Anchor tube with small countersunk head for unobtrusive installation in the joint
Torsion-proof anchor tube
Universal expansion zone for safe anchoring
High loads
Anchor with increased bending moment
Premounted screw for quick installation
German DIBt approval: Z-21.2-589
Technical specifications :
Anchor diameter: 8 mm
Diameter of countersunk head: 12 mm
Drill hole depth h1 ≥: 80 mm
Embedment depth hef ≥: 70 mm
Screw drive: TORX T30
German DIBt approval: Z-21.2-589
Characteristic loads:
Building material class A:
Normal weight concrete ≥ C 12/15 acc. to EN 206-1: 1.0 kN
Pre-cast concrete Panel ≥ B15: 0.25 kN
Building material class B:
Clay bricks(≥ Mz 12) acc. to DIN 105: 0.4 kN
Solid lime sandstone (≥ KS 12) acc. to DIN EN 106: 0.4 kN
Solid masonry of lightweight concrete (V) acc. to DIN 18152: 0.2 kN
Building material class C:
Vertically perforated clay bricks (Hlz) acc. to DIN 105: *
Vertical coring reference brick (Hlz) acc. to ÖNORM B 6124: 0.75 kN
Sand-lime perforated bricks (≥ KSL 6) acc. to DIN EN 106: 0.25 kN
Lightweight concrete hollow blocks (≥ HbL 2) acc. to DIN 18151: 0.15 kN
Building material class D:
Lightweight aggregate concrete acc. to TGL: 0.3 kN
*According to approval to be determined throught pull-out testing at the building.
The design loads given are in accordance with the German building code. National safety factors are already incorporated. Please observe the approval.
More information on : www.ejot.de