Self-drilling Roof Screws

View as Grid List
Sort by

EJOT Dabo® TKR-4.8

Applications :
For fixing roofing membrane to sheet steel substructures ≥ 0,75 mm ≤ 1 mm For timber substructures   In combination with EJOT® HTK 50 stress plate EJOT® HTV 82/40 TK stress plate EJOT® stress plate HTV 82/40 F EJOT® stress plate HTV 40 RU        

Properties :
Case-hardened steel Climadur coated - high-quality coating to improve corrosion protection (15 Kesternich cycles, DIN 50018, 1997) Can be delivered belted for EJOT® ECOset installation tool or pre-assembled with EJOT® stress plates HTK for EJOT® ECOset HTK installation tool.        

Technical specifications :
Drill capacity tI + tII: 2.0 mm Drive: H2 cross recess Length determination for: Sheet steel: insulation thickness +20 mm Timber: insulation thickness +30 mm * Min. lengths        

More information on : www.ejot.de

EJOT Dabo® TKE-4.8

Applications :
To fix roofing membrane to substructures made of sheet steel ≥ 0.75 mm ≤ 1.5 mm, timber and wood-based material For renovations For combination with EJOT® stress plates/tube washers        

Properties :
A4 stainless steel with hardened drill point Can be delivered belted for EJOT® ECOset installation tool or pre-assembled with HTK for EJOT® ECOset HTK.        

Technical specifications :
Drill capacity tI + tII: 1.5 mm Drive: H2 cross recess Length determination (min. lengths) Sheet steel: Insulation thickness + 20 mm Timber: Insulation thickness + 30 mm        

More information on : www.ejot.de

EJOT Dabo® SW8 RT-4.8

Applications :
To secure roofing membrane to sheet steel substructures ≥ 0.75 mm ≤ 1 mm For special requirements of resistance to imposed loads In combination with EJOT® stress plate HTV 82/40 For timber substructures        

Properties :
Case-hardened steel Climadur coated - high-quality coating to improve corrosion protection (15 Kesternich cycles, DIN 50018, 1997)        

Technical specifications :
Drilling capacity tI + tII: 1.5 mm A/F8 hexagon drive Length determination for: Sheet steel: insulation thickness +20 mm Timber: insulation thickness +30 mm * Min. lengths        

More information on : www.ejot.de

EJOT Dabo® screw SW 8 ET-4,8

Applications :
To fix roofing membrane to substructures made of sheet steel ≥ 0.75 mm ≤ 1.5 mm, timber or wood-based material For combination with EJOT® stress plates For renovation (cf. current Flat Roof Guideline)        

Properties :
A4 stainless steel with hardened steel drill point With high thread to prevent screw head        

Technical specifications :
Drilling capacity: 1.5 mm Drive: Hexagon A/F8 Length determination (min. lengths) Sheet steel: Insulation thickness + 20 mm Timber: Insulation thickness + 30 mm        

More information on : www.ejot.de

EJOT Dabo® VHT-R-4.8

Applications :
To fix roofing membrane to substructures made of sheet steel ≥ 0.5 mm ≤ 0.75 mm, timber and wood-based material In combination with EJOT® HTK 50 stress plate EJOT® HTV 82/40 TK stress plate EJOT® stress plate HTV 82/40 F EJOT® stress plate HTV 40 RU Note For thicker and/or two-ply sheet steel we recommend use of the EJOT Dabo® screw TKR-4.8        

Properties :
Case-hardened steel Climadur coated - high-quality coating to improve corrosion protection (15 Kesternich cycles, DIN 50018, 1997)        

Technical specifications :
Drilling capacity: 0.75 mm Drive: H2 cross recess        

More information on : www.ejot.de

EJOT Dabo® SW8 RT-4.8 belted

Applications :
To secure roofing membrane to sheet steel substructures ≥ 0.75 mm ≤ 1 mm For special requirements of resistance to imposed loads In combination with EJOT® stress plate HTV 82/40 For timber substructures        

Properties :
Case-hardened steel Climadur coated - high-quality coating to improve corrosion protection (15 Kesternich cycles, DIN 50018, 1997)        

Technical specifications :
Drill capacity tI + tII: 2.0 mm A/F8 hexagon drive Length determination for: Sheet steel: insulation thickness +20 mm Timber: insulation thickness +30 mm * Min. lengths        

More information on : www.ejot.de