Applications :
For fixing roofing membrane to sheet steel substructures ≥ 0,75 mm ≤ 1 mm
For timber substructures
In combination with
EJOT® HTK 50 stress plate
EJOT® HTV 82/40 TK stress plate
EJOT® stress plate HTV 82/40 F
EJOT® stress plate HTV 40 RU
Properties :
Case-hardened steel
Climadur coated - high-quality coating to improve corrosion protection (15 Kesternich cycles, DIN 50018, 1997)
Can be delivered belted for EJOT® ECOset installation tool or pre-assembled with EJOT® stress plates HTK for EJOT® ECOset HTK installation tool.
Technical specifications :
Drill capacity tI + tII: 2.0 mm
Drive: H2 cross recess
Length determination for:
Sheet steel: insulation thickness +20 mm
Timber: insulation thickness +30 mm
* Min. lengths
More information on : www.ejot.de
Applications :
To fix roofing membrane to substructures made of sheet steel ≥ 0.75 mm ≤ 1.5 mm, timber and wood-based material
For renovations
For combination with EJOT® stress plates/tube washers
Properties :
A4 stainless steel with hardened drill point
Can be delivered belted for EJOT® ECOset installation tool or pre-assembled with HTK for EJOT® ECOset HTK.
Technical specifications :
Drill capacity tI + tII: 1.5 mm
Drive: H2 cross recess
Length determination (min. lengths)
Sheet steel: Insulation thickness + 20 mm
Timber: Insulation thickness + 30 mm
More information on : www.ejot.de
Applications :
To secure roofing membrane to sheet steel substructures ≥ 0.75 mm ≤ 1 mm
For special requirements of resistance to imposed loads
In combination with EJOT® stress plate HTV 82/40
For timber substructures
Properties :
Case-hardened steel
Climadur coated - high-quality coating to improve corrosion protection (15 Kesternich cycles, DIN 50018, 1997)
Technical specifications :
Drilling capacity tI + tII: 1.5 mm
A/F8 hexagon drive
Length determination for:
Sheet steel: insulation thickness +20 mm
Timber: insulation thickness +30 mm
* Min. lengths
More information on : www.ejot.de
Applications :
To fix roofing membrane to substructures made of sheet steel ≥ 0.75 mm ≤ 1.5 mm, timber or wood-based material
For combination with EJOT® stress plates
For renovation (cf. current Flat Roof Guideline)
Properties :
A4 stainless steel with hardened steel drill point
With high thread to prevent screw head
Technical specifications :
Drilling capacity: 1.5 mm
Drive: Hexagon A/F8
Length determination (min. lengths)
Sheet steel: Insulation thickness + 20 mm
Timber: Insulation thickness + 30 mm
More information on : www.ejot.de
Applications :
To fix roofing membrane to substructures made of sheet steel ≥ 0.5 mm ≤ 0.75 mm, timber and wood-based material
In combination with
EJOT® HTK 50 stress plate
EJOT® HTV 82/40 TK stress plate
EJOT® stress plate HTV 82/40 F
EJOT® stress plate HTV 40 RU
Note
For thicker and/or two-ply sheet steel we recommend use of the EJOT Dabo® screw TKR-4.8
Properties :
Case-hardened steel
Climadur coated - high-quality coating to improve corrosion protection
(15 Kesternich cycles, DIN 50018, 1997)
Technical specifications :
Drilling capacity: 0.75 mm
Drive: H2 cross recess
More information on : www.ejot.de
Applications :
To secure roofing membrane to sheet steel substructures ≥ 0.75 mm ≤ 1 mm
For special requirements of resistance to imposed loads
In combination with EJOT® stress plate HTV 82/40
For timber substructures
Properties :
Case-hardened steel
Climadur coated - high-quality coating to improve corrosion protection (15 Kesternich cycles, DIN 50018, 1997)
Technical specifications :
Drill capacity tI + tII: 2.0 mm
A/F8 hexagon drive
Length determination for:
Sheet steel: insulation thickness +20 mm
Timber: insulation thickness +30 mm
* Min. lengths