Filter by:

Clear All

ETICS Anchors

View as Grid List
Sort by

EJOT® EJOT H1 eco

Applications :
Universal hammer-in anchor   Approved for all material classes (A, B, C, D, E) For all insulation boards For surface fixed installation With European Technical Approval (ETA)        

Properties :
Approved for concrete, solid and perforated masonry Solid steel nail (break-proof) Low profile washer face Plastic injection element to reduce thermal transmission (0,001 W/K) Can be used with an additional spreader washer KShort embedment depth, reduced drilling High loads for your security Economic anchor usage Premounted nail for quick installation        

Technical specifications :
Anchor diameter: 8 mm Washer diameter: 60 mm Drill hole depth h1 ≥: 35 mm  Embedment depth hef≥: 25 mm Point thermal transmission χ: 0.001 W/K  Use categories acc. to ETA: A, B, C European Technical Approval: ETA-11/0192 Characteristic loads: Building material class A: Normal weight concrete C 12/15 acc. to EN 206-1: 0.9 kN Normal weight concrete C 16/20 - C 50/60 acc. to EN 206-1: 0.9 kN Building material class B: Clay bricks (Mz) acc. to DIN 105: 0.9 kN Solid lime sandstone (KS) acc. to DIN EN 106: 0.9 kN Building material class C: Vertically perforated clay brick (Hlz) acc. to DIN 105, bulk density ≥ 1.2 kg/dm3: 0.75 kN Vertically perforated clay brick (Hlz) acc. to DIN 105, bulk density ≥ 0.9 kg/dm3: 0.6 kN Sand-lime perforated (KSL) acc. to DIN EN 106: 0.9 kN For calculation of design loads the national safety factors have to be included (e.g. Germany: 3). Please observe the approval.        

More information on : www.ejot.de

EJOT® ejotherm STR U 2G

Applications :
Universal screw-in anchor for countersunk and surface fixed installation in concrete and masonry   For all substrates (A, B, C, D, E) For all insulation boards For countersunk and surface fixed instalaltion For homogeneous surfaces and even rendering Up to 40% faster installation With European Technical Approval (ETA)        

Properties :
Approved for all building materials Countersunk installation - EJOT STR principle with ejotherm STR cap for homogeneous surfaces and even rendering - quick and easy without milling dust Up to 40% fastener installation Reduced thermal transmission (0.001 W/K) Surface fixed installation using ejotherm STR plug Short embedment depths, high loads for maximum safety and economic anchor usage Permanent contact pressure Premounted screw for quick installation 100% setting control: the countersunk installation of the washer indicates safe anchorage        

Technical specifications :
Anchor diameter: 8 mm Washer diameter: 60 mm Drill hole depth, countersunk installation h1 ≥: 50 mm (90 mm) Drill hole depth, surface fixed installation h2 ≥: 35 mm (75 mm) Anchorage depth hef≥: 25 mm (65 mm) Screw drive: TORX T30 Point thermal transmission χ  countersunk installation: 0,001 W/K surface fixed installation: 0,002 W/K Use categories acc. to ETA*: A, B, C, D, E German DIBt approval: Z-21.2-1769 European Technical Approval: ETA-04/0023 Values in parentheses: anchoring in aerated concrete (use category E) *Specification according to ÖNORM B 6124 for concrete, solid brick and vertical brick Characteristic loads: Building material class A: Normal weight concrete C 12/15 acc. to EN 206-1: 1.5 kN Normal weight concrete C 16/20 - C 50/60 acc. to EN 206-1: 1.5 kN Pre-cast concrete panel C16/20 - C50/60: 1.5 kN Building material class B: Clay bricks (Mz) acc. to DIN 105: 1.5 kN Solid lime sandstone (KS) acc. to DIN EN 106: 1.5 kN Solid masonry of lightweight concrete (V) acc. to DIN 18152: 0.6 kN Building material class C: Vertically perforated clay bricks (Hlz) acc. to 105: 1.2 kN Vertical coring reference bricks (Hlz) acc. to ÖNORM B 6124: 0.75 kN Sand-lime perforated (KSL) acc. to EN 106: 1.5 kN Lightweight concrete hollow blocks (HbL)acc. to DIN 18151: 0.6 kN Baustoffklasse D: Lightweight aggregate concrete (LAC): 0.9 kN Building material class E: Autoclaved aerated concrete P2 - P7: 0.75 kN For calculation of design loads the national safety factors have to be included (e.g. Germany: 3). Please observe the approval.        

More information on : www.ejot.de

EJOT® ejotherm NT U

Applications :
Universal hammer-in anchor   For concrete, solid and perforated masonry (A, B, C) For all insulation boards With European Technical Approval (ETA)        

Properties :
Approved for concrete, solid and perforated masonry Solid steel nail (break-proof) Plastic injection moulding to reduce thermal transmission Can be used with an additional spreader washer Short embedment depths, reduced drilling High loads for your security Economic anchor usage Premounted nail for quick installation        

Technical specifications :
Anchor diameter: 8 mm Washer diameter: 60 mm Drill hole depth h1≥: 35 mm  Embedment depth hef≥: 25 mm Point thermal transmission χ: 0.002 W/K  Use categories ETA: A, B, C European Technical Approval: ETA-05/0009 Characteristic loads: Building material class A: Normal weight concrete C 12/15 acc. to EN 206-1: 1.2 kN Normal weight concrete C 16/20 - C 50/60 acc. to EN 206-1: 1.2 kN Building material class B: Clay bricks(Mz) acc. to DIN 105: 1.5 kN Solid lame sandstone (KS) acc. to DIN EN 106: 1.5 kN Solid masonry of lightweight concrete (V) acc. to DIN 18152: 0.5 kN Building material class C: Vertically perforated clay bricks (Hlz) acc. to DIN 105: 0.9 kN Sand-lime perforated bricks (KSL) acc. to DIN EN 106: 1.5 kN Lightweight concrete hollow blocks (HbL) acc. to DIN 18151: 0.5 kN        

More information on : www.ejot.de

EJOT® ejotherm NTK U

Applications :
Universal hammer-in anchor   For concrete, solid and perforated masonry (A, B, C) For all insulation boards With European Technical Approval (ETA)        

Properties :
Approved for concrete, solid and perforated masonry Upon installation, the washer face de-couples from the sleeve, ensuring a flush finish with the insulation surface Safe and smooth installation with built-in setting control through the EJOT telescope effect Zero thermal transmission Minimised risk of breaking nails due to fibre-reinforced composites Premounted expansion nail for quick installation        

Technical specifications :
Anchor diameter: 8 mm Washer diameter: 60 mm Drill hole depth h1 ≥: 50 mm  Embedment depth hef≥: 40 mm Point thermal transmission χ: 0.000 W/K  Use categories ETA: A, B, C German DIBt approval: Z-21.2-1844 European Technical Approval: ETA-07/0026 Characteristic loads: Building material class A: Normal weight concrete C 12/15 acc. to EN 206-1: 0.6 kN Normal weight concrete C 16/20 - C 50/60 acc. to EN 206-1: 0.9 kN Building material class B: Clay bricks (Mz) acc. to DIN 105: 0.9 kN Solid lame sandstone (KS) acc. to DIN EN 106: 0.9 kN Building material class C: Vertically perforated clay bricks (Hlz) acc. to DIN 105: 0.6 kN Sand-lime perforated bricks (KSL) acc. to DIN EN 106: 0.9 kN *For calculation of design loads the national safety factors have to be included (e.g. Germany: 3). Please observe the approval.        

More information on : www.ejot.de

EJOT® SDF-S plus 8UB

Applications :
Brick slip system anchor for concrete and masonry For concrete, solid and perforated masonry Anchor tube with small countersunk head for unobtrusive installation in the joint        

Properties :
Approved for concrete, solid and perforated masonry (A, B, C, D) Anchor tube with small countersunk head for unobtrusive installation in the joint Torsion-proof anchor tube Universal expansion zone for safe anchoring High loads Anchor with increased bending moment Premounted screw for quick installation German DIBt approval: Z-21.2-589        

Technical specifications :
Anchor diameter: 8 mm Diameter of countersunk head: 12 mm Drill hole depth h1 ≥: 80 mm Embedment depth hef ≥:  70 mm Screw drive: TORX T30 German DIBt approval: Z-21.2-589 Characteristic loads: Building material class A: Normal weight concrete ≥ C 12/15 acc. to EN 206-1: 1.0 kN Pre-cast concrete Panel ≥ B15: 0.25 kN Building material class B: Clay bricks(≥ Mz 12) acc. to DIN 105: 0.4 kN Solid lime sandstone (≥ KS 12) acc. to DIN EN 106: 0.4 kN Solid masonry of lightweight concrete (V) acc. to DIN 18152: 0.2 kN Building material class C: Vertically perforated clay bricks (Hlz) acc. to DIN 105: * Vertical coring reference brick (Hlz) acc. to ÖNORM B 6124: 0.75 kN Sand-lime perforated bricks (≥ KSL 6) acc. to DIN EN 106: 0.25 kN Lightweight concrete hollow blocks (≥ HbL 2) acc. to DIN 18151: 0.15 kN Building material class D: Lightweight aggregate concrete acc. to TGL: 0.3 kN *According to approval to be determined throught pull-out testing at the building. The design loads given are in accordance with the German building code. National safety factors are already incorporated. Please observe the approval.          

More information on : www.ejot.de

EJOT® ejotherm STR plug

Applications :
ejotherm STR plug   Special polystyrene (EPS) isolation plug To be used with ejotherm STR U 2G, ejotherm STR U for surface fixed installation ejotherm STR plug is included in the packaging of ejotherm STR H

More information on : www.ejot.de

EJOT® ejotherm STR ring washer MW

Applications :
ejotherm STR cap MW  Specially developed mineral wool insolation cap For countersunk Installation acc. to EJOT STR principle To be used with ejotherm STR U 2G, STR U, STR H, STR H A2 and ejotherm VT 2G

More information on : www.ejot.de

EJOT® ejotherm STR ring washer EPS

Applications :
ejotherm STR cap EPS   Specially developed polystrene (EPS) isolation cap For coutnersunk Installation acc. to EJOT STR principle To be used with ejotherm STR U 2G, ejotherm STR U,ejotherm STR H and STR H A2

Properties :
Colours: White and grey

More information on : www.ejot.de

EJOT® ejotherm STR H

Applications :
Screw fastener for countersunk and surface fixed installation for timber and some steel substrates   For timber and steel (max. 0.75 mm) substrates For all insulation boards For countersunk and surface fixed installation

Properties :
Fastener, consistent of a galvanized steel screw, included washer and EPS sealing plug. Countersunk Installation - EJOT STR principle with ejotherm STR cap for homogeneous surfaces and even rendering - quick and easy without milling dust No drilling necessary Surface fixed Installation using ejotherm STR plug Permanent contact pressure Premounted screw for quick installation 100% setting control: the countersunk Installation of the washer indicates safe anchorage

Technical specifications :
Screw diameter: 6 mm Washer diameter: 60 mm Screw-in depth: 30 - 40 mm Screw drive: TORX T25 Point thermal transmission χ: countersunk installation in timber substrates: 0.001 W/K surface fixed installation in timber substrates: 0.002 W/K Recommended use loads: Wood fibreboards (thickness ≥ 17.0 mm): 0.25 kN Chipboards (thickness ≥ 13.0 mm): 0.25 kN Gypsum fibreboards (thickness ≥ 12.5 mm): 0.15 kN OSB plates (thickness ≥ 16.0 mm): 0.25 kN Solid wood plates (thickness ≥ 27.0 mm): 0.25 kN The recommended use loads are calculated with a safety factor of 3. They may differ according to the object.

More information on : www.ejot.de

EJOT® Iso-Spiral anchor

Applications :
EJOT Iso-Spiral anchor for fastening of attachments Fastening solution for light attachments on ETICS facades        

Properties :
Recommended load: max. 5 kg per mounting point No thermal bridging Can be installed with commercial drill / drive tool        

Technical specifications :
Retrofit installation through the finish render possible: simply screw through the final rendering into the insulation (drive TORX T40, usually without pre-drilling), fasten a 4-5 mm screw and fix the attachment        

More information on : www.ejot.de

EJOT® ejotherm STR U

Applications :
Universal screw-in anchor for countersunk and surface fixed installation in concrete and masonry   For all substrates (A, B, C, D, E) For all insulation boards For countersunk and surface fixed instalaltion For homogeneous surfaces and even rendering With European Technical Approval (ETA)        

Properties :
Approved for all building materials Countersunk installation - EJOT STR principle with ejotherm STR cap for homogeneous surfaces and even rendering - quick and easy without milling dust Surface fixed installation using ejotherm STR plug Short embedment depths, high loads for maximum safety and economic anchor usage Permanent contact pressure Premounted screw for quick installation 100% setting control: the countersunk installation of the washer indicates safe anchorage        

Technical specifications :
Anchor diameter: 8 mm Washer diameter: 60 mm Drill hole depth, countersunk installation h1 ≥: 50 mm (90 mm) Drill hole depth, surface fixed installation h2 ≥: 35 mm (75 mm) Anchorage depth hef≥: 25 mm (65 mm) Screw drive: TORX T30 Point thermal transmission χ  countersunk installation: 0,002 W/K surface fixed installation: 0,002 W/K Use categories acc. to ETA*: A, B, C, D, E German DIBt approval: Z-21.2-1769 European Technical Approval: ETA-04/0023 Values in parentheses: anchoring in aerated concrete (use category E) *Specification according to ÖNORM B 6124 for concrete, solid brick and vertical brick Characteristic loads: Building material class A: Normal weight concrete C 12/15 acc. to EN 206-1: 1.5 kN Normal weight concrete C 16/20 - C 50/60 acc. to EN 206-1: 1.5 kN Pre-cast concrete panel C16/20 - C50/60: 1.5 kN Building material class B: Clay bricks (Mz) acc. to DIN 105: 1.5 kN Solid lime sandstone (KS) acc. to DIN EN 106: 1.5 kN Solid masonry of lightweight concrete (V) acc. to DIN 18152: 0.6 kN Building material class C: Vertically perforated clay bricks (Hlz) acc. to 105: 1.2 kN Vertical coring reference bricks (Hlz) acc. to ÖNORM B 6124: 0.75 kN Sand-lime perforated (KSL) acc. to EN 106: 1.5 kN Lightweight concrete hollow blocks (HbL)acc. to DIN 18151: 0.6 kN Baustoffklasse D: Lightweight aggregate concrete (LAC): 0.9 kN Building material class E: Autoclaved aerated concrete P2 - P7: 0.75 kN For calculation of design loads the national safety factors have to be included (e.g. Germany: 3). Please observe the approval.        

More information on : www.ejot.de

EJOT® ejotherm STR tool spare bits

Applications :
For surface fixed installation of ejotherm STR U 2G and ejotherm STR U: ejotherm STR bit TX30-M8 x 52 For countersunk installation of ejotherm STR H: ejotherm STR bit TX25-M8 x 31

More information on : www.ejot.de

EJOT® ejotherm STR-tool 2GS

Applications :
Specially developed tool for countersunk installation of ejotherm STR U 2G according to the EJOT STR principle Also compatible for use with ejotherm STR U und ejotherm STR H and STR H A2 For reliable and easy Installation according to the EJOT STR principle For all insulation boards

Properties :
Adjustment shaft with hex shank for easy use with standard drills Patented mechanism enables quick and easy adjustment to the required anchor length Easy conversion from ejotherm STR tool 2GS for surface fixed installation Robust design for long service life Worn parts can be changed quickly Set contains: ejotherm STR-tool 2GS, additional cutting discs, offset screw driver as well as bits for all applications

More information on : www.ejot.de

EJOT® DDA

Applications :
Ceiling insulation anchor For fastening of ceiling and acoustic insulation Recommended substrate: Concrete  

Properties :
Easy installation: drill, hammer, done! Available in colours beige or white

Technical specifications :
Head diameter: 25 mm Drill hole Diameter: 8 mm Drill hole depth h1 &ge:; 35 mm Embedment depth hef &ge:; 25 mm Recommended substrate: Concrete

More information on : www.ejot.de

EJOT® DDS

Applications :
Fastening ceiling and acoustic insulation boards to concrete substrates

Properties :
Steel screw with self-drilling thread for a secure fastening Easy installation Short embedment depth Plastic injection moulded head with wood wool structure available in beige or white Can be used in conjunction with the DDT 70 washer for load spreading

Technical specifications :
Head diameter incl. plastic injection moulding:25 mm Drill hole diameter 6 mm Embedment depth in concrete: 20 mm Screw drive: TORX T30 Recommended substrate Concrete

More information on : www.ejot.de

EJOT® DDS-Z

Applications :
Ceiling insulation screw For a secure fastening of ceiling and acoustic boards With German DIBt approval Recommended substrate: Concrete        

Properties :
For installation in cracked and non-cracked concrete Steel screw with duplex coating and self-tapping thread for reliable fastening Corrosion resistance classification C1-C3 Easy installation: drill, fasten, done Minimal embedment depth Standard screw head colour: white Special service: coloured lacquering of the fastener heads        

Technical specifications :
Head diameter: 24 mm Drill hole diameter: 6 mm Drill hole depth h1 ≥: 35mm  Embedment depth hef≥: 25 mm Screw drive: TORX T-30  Recommended substrate: Concrete Building material class: A2 Corrosion resistance classification: C1 - C3 DIBt approval: Z-21.8-1980   Characteristic load:   Cracked and uncracked normal weight concrete C 20/25 - C 50/60 NRK<7sub>: 0.9 kN *For further technical specification, please refer to the relevant technical data sheet.        

More information on : www.ejot.de

EJOT® DDT

Applications :
Used in conjunction with the DDS anchor for ridgid insulation boards to spread the load        

Properties :
Galvanised steel washer        

Technical specifications :
70mm diameter 8mm inner diameter        

More information on : www.ejot.de

EJOT ejotherm Adapter za podešavanje SDS-plus

Anwendungen :
Verstellschaft SDS-plus Alternativer Verstellschaft mit SDS-plus Aufnahme für ejotherm STR-tool 2GS

Weitere Informationen unter: www.ejot.de

EJOT® TE 60/110

Applications :
For fastening External Thermal Insulation Composite Systems with problematic substrates To combine with EJOT SDF-S plus 8UB Available in two lengths With European Technical Assessment For surface fixed installation Can be combined with additional washers EJOT SBL 140 plus and EJOT VT 90 Washer diameter: 60 mm Special sealing plug made of polystyrene (EPS) included in the scope of supply

Technical specifications :
Shaft length EJOT TE 60/50: 50 mm Shaft length EJOT TE 60/110: 110 mm Washer Diameter: 60 mm Screw drive: TORX T30 Drill hole depth h1: ≥ 80 mm Embedment depth hef: ≥ 70 mm Point thermal transmission Χ EJOT TE 60/50 with insulation thicknesses 60 - 180 mm: 0.002 W/K Point thermal transmission Χ EJOT TE 60/110 with insulation thicknesses 120 - 150 mm: 0.00 W/K Point thermal transmission Χ EJOT TE 60/110 with insulation thicknesses 150 - 240 mm: 0.001 W/K European Technical Assessment: ETA-04/0064

More information on : www.ejot.de

EJOT® TE 60/50

Applications :
Fastening of External Thermal Insulation Systems on problematic substrates To combine with EJOT SDF-S plus 8UB

Technical specifications :
Technical data EJOT TE 60/50 and 60/110 in combinaton with EJOT SDF-S plus 8UB Shaft length EJOT TE 60/50: 50 mm Shaft length EJOT TE 60/110: 110 mm Washer diameter: 60 mm Screw drive: TORX T30 Drill hole depth h1 ≥ : 80 mm Embedment depth hef ≥ : 70 mm Point thermal transmission χ TE 60/50: 0.002 W/K Point thermal transmission χ TE 60/110 with insulation thickness 120-150 mm: 0.000 W/K Point thermal transmission χ TE 60/110 with insulation thickness 150-240: 0.001 W/K European Technical Approval ETA-04/0064

More information on : www.ejot.de

EJOT® SDP-S plus 8

Applications :
Brick slip system anchor for aerated concrete For aerated concrete (E) Anchor tube with small countersunk head for unobtrusive installation in the joint

Properties :
Approved for aerated concrete (E) Anchor tube with small countersunk head for unobtrusive installation in the joint Distort-proof anchor tube Special expansion zone with hooks for form-fit anchoring High loads Premounted screw for quick installation German DIBt approval: Z-21.2-967

Technical specifications :
Anchor diameter: 8 mm Diameter of countersunk head: 12 mm Drill hole depth h1 ≥: 120 mm Embedment depth hef≥:  110 mm Screw drive: TORX T30 German DIBt approval: Z-21.2-967 Design loads: Building material class E: Autoclaved aerated concrete acc. DIN (2 and 3,3 resp.): 0.2 kN Autoclaved aerated concrete acc. DIN (4 and 4,4 resp.): 0.5 kN Autoclaved aerated concrete acc. TGL (Laußig plant): 0.3 kN Autoclaved aerated concrete acc. DIN TGL (Parchim plant): 0.5 kN The design loads given are in accordance with the German building code. National safety factors are already incorporated. Please observe the approval.

More information on : www.ejot.de

EJOT VSD 8U-V

Anwendungen :
 Verblend-Sanierdübel mit verzinkter Stahlschraube für zweischaliges Mauerwerk Für die nächträgliche Sanierung der Vormauerschale bei Objekten in Industrieatmosphäre und in Meeresnähe Kostengünstige Wiederherstellung der Standsicherheit Für Beton, Voll- und Lochsteine (A, B, C) Mit allgemeiner bauaufsichtlicher Zulassung Hinweis: Nach der Sanierung der Vormauerschale muss zusätzlich ein Fassadensystem mit einer Wärmedämmung (z. B. WDVS) in einer Dicke von mindestens 60 mm aufgebracht werden. Zusätzlich ist darauf zu achten, dass keine Belüftung hinter der Vormauerschale vorhanden ist.        

Eigenschaften :
Bauaufsichtlich zugelassender Dübel zur Sanierung von zweischaligem Mauerwerk Universalspreizzone: sichere Verankerung in Tragschalen aus Beton, Voll- und Lochsteinmauerwerk Doppelspreizdübel: verandkert gleichzeitig in tragender Wand und Vormauerschale Saubere und schnelle Verarbeitung (kein Mörtel notwendig) 100% Setzkontrolle Temperaturunabhängige Montagezeiten Verarbeitung bereits ab 0°C        

Technische Daten :
Kennwerte: Bohrlochtiefe h1≥: 80 mm Bohrlochdurchmesser: 8 mm  Verankerungstiefe hef≥: 70 mm Schraubantrieb: TORX T25 DIBt-Zulassung: Z-21.2-1652 Zulässige Lasten: Baustoffklasse A: Normalbeton ≥ C 12/15 nach EN 206-1: 1,0 kN Baustoffklasse B: Mauerziegel (Mz) nach DIN 105: 0,4 kN Kalksandvollstein (KS) nach DIN EN 106: 0,4 kN Vollsteine aus Leichtbeton (V) nach DIN 18152: 0,2 kN Baustoffklasse C: Hochlochziegel (Hlz) nach DIN 105: 0,25 kN* Kalksandlochstein (KSL) nach DIN EN 106: 0,25 kN Hohlblock aus Leichtbeton (HbL) nach DIN 18151: 0,15 kN * Die angegebenen zulässigen Lasten entsprechen geltenden deutschen Bauvorschriften. Nationale Sicherheitsfaktoren sind bereits berücksichtigt. Bitte Zulassung beachten.        

Weitere Informationen unter: www.ejot.de

EJOTHERM Udarni Tipl H2

Anwendungen :
Zur Befestigung von außenseitigen Wärmedämm- Verbundsysteme mit Putzschicht Zur Befestigung von Brandriegeln Für die Verankerung in allen Untergründen (A, B, C, D, E) Für alle Dämmstoffplatten Für die oberflächenbündige Montage

Eigenschaften :
Zugelassen für alle Baustoffklassen (A, B, C, D, E) Duale Spreizzone (25/45 mm) für optimalen Halt auch in kritische Untergründe Axial verschiebbarer Dübelteller für optimales Setzverhalten (Tellereinzug) Reduzierung von Wärmebrücken durch variablen Unterkopfbereich und kunststoffumspritzten Stahlnagel (0,001 W/K) Schlanker Dübelteller mit hoher Tellersteifigkeit Vormontiert für eine schnelle Montage Mit Zusatztteller montierbar

Technische Daten :
Dübeldurchmesser: 8 mm Tellerdurchmesser: 60 mm Bohrlochtiefe h1: ≥ 35 mm (55 mm) Verankerungstiefe hef: ≥ 25 mm (45 mm) Punktbezogener Wärmedurchgangskoeffizient λ: 0,001 W/K Nutzungskategorien ETA*: A, B, C, D, E Werte in Klammern: Verankerung in haufwerksporigen Leichtbeton und Porenbeton (Nutzungskategorie D, E) *Geeignet gemäß ÖNorm B 6124 für Beton und Vollstein

Weitere Informationen unter: www.ejot.de

EJOT® ejotherm VT 2G

Applications :
Specifically matched combination washer for ejotherm STR U 2G for countersunk installation into all mineral wool insulation boards WAP-zg (type WV)   ejotherm VT 2G continues to promote the countersunk installation acc. to STR principle in all mineral wool insulation boards with a low tensil strength WAP-zg (type WV) For homogeneous surfaces and even rendering With European Technical Approval (ETA)        

Properties :
Low point thermal transmission (Chi value 0.001 W/K) Reduced anchor marks No additional tool required Permanent contact pressure Anchor locates easily in the washer with a firm "click" 100% setting control        

Technical specifications :
Washer diameter: 110 mm German DIBt approval: Z-21.2-1769 European Technical Approval: ETA-04-0023  The quantity of anchors can be found in the mineral wool approvals for washers ≥90 mm..        

More information on : www.ejot.de