Filter by:
Clear AllApplications :
Universal hammer-in anchor
Approved for all material classes (A, B, C, D, E)
For all insulation boards
For surface fixed installation
With European Technical Approval (ETA)
Properties :
Approved for concrete, solid and perforated masonry
Solid steel nail (break-proof)
Low profile washer face
Plastic injection element to reduce thermal transmission (0,001 W/K)
Can be used with an additional spreader washer
KShort embedment depth, reduced drilling
High loads for your security
Economic anchor usage
Premounted nail for quick installation
Technical specifications :
Anchor diameter: 8 mm
Washer diameter: 60 mm
Drill hole depth h1 ≥: 35 mm
Embedment depth hef≥: 25 mm
Point thermal transmission χ: 0.001 W/K
Use categories acc. to ETA: A, B, C
European Technical Approval: ETA-11/0192
Characteristic loads:
Building material class A:
Normal weight concrete C 12/15 acc. to EN 206-1: 0.9 kN
Normal weight concrete C 16/20 - C 50/60 acc. to EN 206-1: 0.9 kN
Building material class B:
Clay bricks (Mz) acc. to DIN 105: 0.9 kN
Solid lime sandstone (KS) acc. to DIN EN 106: 0.9 kN
Building material class C:
Vertically perforated clay brick (Hlz) acc. to DIN 105, bulk density ≥ 1.2 kg/dm3: 0.75 kN
Vertically perforated clay brick (Hlz) acc. to DIN 105, bulk density ≥ 0.9 kg/dm3: 0.6 kN
Sand-lime perforated (KSL) acc. to DIN EN 106: 0.9 kN
For calculation of design loads the national safety factors have to be included (e.g. Germany: 3). Please observe the approval.
More information on : www.ejot.de
Applications :
Universal screw-in anchor for countersunk and surface fixed installation in concrete and masonry
For all substrates (A, B, C, D, E)
For all insulation boards
For countersunk and surface fixed installation
For homogeneous surfaces and even rendering
Up to 40% faster installation
With European Technical Approval (ETA)
Properties :
Approved for all building materials
Countersunk installation - EJOT STR principle with ejotherm STR cap for homogeneous surfaces and even rendering - quick and easy without milling dust
Up to 40% fastener installation
Reduced thermal transmission (0.001 W/K)
Surface fixed installation using ejotherm STR plug
Short embedment depths, high loads for maximum safety and economic anchor usage
Permanent contact pressure
Premounted screw for quick installation
100% setting control: the countersunk installation of the washer indicates safe anchorage
Technical specifications :
Anchor diameter: 8 mm
Washer diameter: 60 mm
Drill hole depth, countersunk installation h1 ≥: 50 mm (90 mm)
Drill hole depth, surface fixed installation h2 ≥: 35 mm (75 mm)
Anchorage depth hef≥: 25 mm (65 mm)
Screw drive: TORX T30
Point thermal transmission χ
countersunk installation: 0,001 W/K
surface fixed installation: 0,002 W/K
Use categories acc. to ETA*: A, B, C, D, E
German DIBt approval: Z-21.2-1769
European Technical Approval: ETA-04/0023
Values in parentheses: anchoring in aerated concrete (use category E)
*Specification according to ÖNORM B 6124 for concrete, solid brick and vertical brick
Characteristic loads:
Building material class A:
Normal weight concrete C 12/15 acc. to EN 206-1: 1.5 kN
Normal weight concrete C 16/20 - C 50/60 acc. to EN 206-1: 1.5 kN
Pre-cast concrete panel C16/20 - C50/60: 1.5 kN
Building material class B:
Clay bricks (Mz) acc. to DIN 105: 1.5 kN
Solid lime sandstone (KS) acc. to DIN EN 106: 1.5 kN
Solid masonry of lightweight concrete (V) acc. to DIN 18152: 0.6 kN
Building material class C:
Vertically perforated clay bricks (Hlz) acc. to 105: 1.2 kN
Vertical coring reference bricks (Hlz) acc. to ÖNORM B 6124: 0.75 kN
Sand-lime perforated (KSL) acc. to EN 106: 1.5 kN
Lightweight concrete hollow blocks (HbL)acc. to DIN 18151: 0.6 kN
Baustoffklasse D:
Lightweight aggregate concrete (LAC): 0.9 kN
Building material class E:
Autoclaved aerated concrete P2 - P7: 0.75 kN
For calculation of design loads the national safety factors have to be included (e.g. Germany: 3). Please observe the approval.
More information on : www.ejot.de
Applications :
Universal hammer-in anchor
For concrete, solid and perforated masonry (A, B, C)
For all insulation boards
With European Technical Approval (ETA)
Properties :
Approved for concrete, solid and perforated masonry
Solid steel nail (break-proof)
Plastic injection moulding to reduce thermal transmission
Can be used with an additional spreader washer
Short embedment depths, reduced drilling
High loads for your security
Economic anchor usage
Premounted nail for quick installation
Technical specifications :
Anchor diameter: 8 mm
Washer diameter: 60 mm
Drill hole depth h1≥: 35 mm
Embedment depth hef≥: 25 mm
Point thermal transmission χ: 0.002 W/K
Use categories ETA: A, B, C
European Technical Approval: ETA-05/0009
Characteristic loads:
Building material class A:
Normal weight concrete C 12/15 acc. to EN 206-1: 1.2 kN
Normal weight concrete C 16/20 - C 50/60 acc. to EN 206-1: 1.2 kN
Building material class B:
Clay bricks(Mz) acc. to DIN 105: 1.5 kN
Solid lame sandstone (KS) acc. to DIN EN 106: 1.5 kN
Solid masonry of lightweight concrete (V) acc. to DIN 18152: 0.5 kN
Building material class C:
Vertically perforated clay bricks (Hlz) acc. to DIN 105: 0.9 kN
Sand-lime perforated bricks (KSL) acc. to DIN EN 106: 1.5 kN
Lightweight concrete hollow blocks (HbL) acc. to DIN 18151: 0.5 kN
More information on : www.ejot.de
Applications :
Universal hammer-in anchor
For concrete, solid and perforated masonry (A, B, C)
For all insulation boards
With European Technical Approval (ETA)
Properties :
Approved for concrete, solid and perforated masonry
Upon installation, the washer face de-couples from the sleeve, ensuring a flush finish with the insulation surface
Safe and smooth installation with built-in setting control through the EJOT telescope effect
Zero thermal transmission
Minimised risk of breaking nails due to fibre-reinforced composites
Premounted expansion nail for quick installation
Technical specifications :
Anchor diameter: 8 mm
Washer diameter: 60 mm
Drill hole depth h1 ≥: 50 mm
Embedment depth hef≥: 40 mm
Point thermal transmission χ: 0.000 W/K
Use categories ETA: A, B, C
German DIBt approval: Z-21.2-1844
European Technical Approval: ETA-07/0026
Characteristic loads:
Building material class A:
Normal weight concrete C 12/15 acc. to EN 206-1: 0.6 kN
Normal weight concrete C 16/20 - C 50/60 acc. to EN 206-1: 0.9 kN
Building material class B:
Clay bricks (Mz) acc. to DIN 105: 0.9 kN
Solid lame sandstone (KS) acc. to DIN EN 106: 0.9 kN
Building material class C:
Vertically perforated clay bricks (Hlz) acc. to DIN 105: 0.6 kN
Sand-lime perforated bricks (KSL) acc. to DIN EN 106: 0.9 kN
*For calculation of design loads the national safety factors have to be included (e.g. Germany: 3). Please observe the approval.
More information on : www.ejot.de
Applications :
Brick slip system anchor for concrete and masonry
For concrete, solid and perforated masonry
Anchor tube with small countersunk head for unobtrusive installation in the joint
Properties :
Approved for concrete, solid and perforated masonry (A, B, C, D)
Anchor tube with small countersunk head for unobtrusive installation in the joint
Torsion-proof anchor tube
Universal expansion zone for safe anchoring
High loads
Anchor with increased bending moment
Premounted screw for quick installation
German DIBt approval: Z-21.2-589
Technical specifications :
Anchor diameter: 8 mm
Diameter of countersunk head: 12 mm
Drill hole depth h1 ≥: 80 mm
Embedment depth hef ≥: 70 mm
Screw drive: TORX T30
German DIBt approval: Z-21.2-589
Characteristic loads:
Building material class A:
Normal weight concrete ≥ C 12/15 acc. to EN 206-1: 1.0 kN
Pre-cast concrete Panel ≥ B15: 0.25 kN
Building material class B:
Clay bricks(≥ Mz 12) acc. to DIN 105: 0.4 kN
Solid lime sandstone (≥ KS 12) acc. to DIN EN 106: 0.4 kN
Solid masonry of lightweight concrete (V) acc. to DIN 18152: 0.2 kN
Building material class C:
Vertically perforated clay bricks (Hlz) acc. to DIN 105: *
Vertical coring reference brick (Hlz) acc. to ÖNORM B 6124: 0.75 kN
Sand-lime perforated bricks (≥ KSL 6) acc. to DIN EN 106: 0.25 kN
Lightweight concrete hollow blocks (≥ HbL 2) acc. to DIN 18151: 0.15 kN
Building material class D:
Lightweight aggregate concrete acc. to TGL: 0.3 kN
*According to approval to be determined throught pull-out testing at the building.
The design loads given are in accordance with the German building code. National safety factors are already incorporated. Please observe the approval.
More information on : www.ejot.de
Applications :
ejotherm STR plug
Special polystyrene (EPS) isolation plug
To be used with ejotherm STR U 2G, ejotherm STR U for surface fixed installation
ejotherm STR plug is included in the packaging of ejotherm STR H
More information on : www.ejot.de
Applications :
ejotherm STR cap MW
Specially developed mineral wool insolation cap
For countersunk Installation acc. to EJOT STR principle
To be used with ejotherm STR U 2G, STR U, STR H, STR H A2 and ejotherm VT 2G
More information on : www.ejot.de
Applications :
ejotherm STR cap EPS
Specially developed polystrene (EPS) isolation cap
For coutnersunk Installation acc. to EJOT STR principle
To be used with ejotherm STR U 2G, ejotherm STR U,ejotherm STR H and STR H A2
Properties :
Colours: White and grey
More information on : www.ejot.de
Applications :
Screw fastener for countersunk and surface fixed installation
for timber and some steel substrates
For timber and steel (max. 0.75 mm) substrates
For all insulation boards
For countersunk and surface fixed installation
Properties :
Fastener, consistent of a galvanized steel screw, included washer and EPS sealing plug.
Countersunk Installation - EJOT STR principle with ejotherm STR cap for homogeneous surfaces and even rendering - quick and easy without milling dust
No drilling necessary
Surface fixed Installation using ejotherm STR plug
Permanent contact pressure
Premounted screw for quick installation
100% setting control: the countersunk Installation of the washer indicates safe anchorage
Technical specifications :
Screw diameter: 6 mm
Washer diameter: 60 mm
Screw-in depth: 30 - 40 mm
Screw drive: TORX T25
Point thermal transmission χ:
countersunk installation in timber substrates: 0.001 W/K
surface fixed installation in timber substrates: 0.002 W/K
Recommended use loads:
Wood fibreboards (thickness ≥ 17.0 mm): 0.25 kN
Chipboards (thickness ≥ 13.0 mm): 0.25 kN
Gypsum fibreboards (thickness ≥ 12.5 mm): 0.15 kN
OSB plates (thickness ≥ 16.0 mm): 0.25 kN
Solid wood plates (thickness ≥ 27.0 mm): 0.25 kN
The recommended use loads are calculated with a safety factor of 3. They may differ according to the object.
More information on : www.ejot.de
Applications :
EJOT Iso-Spiral anchor for fastening of attachments
Fastening solution for light attachments on ETICS facades
Properties :
Recommended load: max. 5 kg per mounting point
No thermal bridging
Can be installed with commercial drill / drive tool
Technical specifications :
Retrofit installation through the finish render possible:
simply screw through the final rendering into the insulation (drive TORX T40, usually without pre-drilling), fasten a 4-5 mm screw and fix the attachment
More information on : www.ejot.de
Applications :
Universal screw-in anchor for countersunk and surface fixed installation in concrete and masonry
For all substrates (A, B, C, D, E)
For all insulation boards
For countersunk and surface fixed instalaltion
For homogeneous surfaces and even rendering
With European Technical Approval (ETA)
Properties :
Approved for all building materials
Countersunk installation - EJOT STR principle with ejotherm STR cap for homogeneous surfaces and even rendering - quick and easy without milling dust
Surface fixed installation using ejotherm STR plug
Short embedment depths, high loads for maximum safety and economic anchor usage
Permanent contact pressure
Premounted screw for quick installation
100% setting control: the countersunk installation of the washer indicates safe anchorage
Technical specifications :
Anchor diameter: 8 mm
Washer diameter: 60 mm
Drill hole depth, countersunk installation h1 ≥: 50 mm (90 mm)
Drill hole depth, surface fixed installation h2 ≥: 35 mm (75 mm)
Anchorage depth hef≥: 25 mm (65 mm)
Screw drive: TORX T30
Point thermal transmission χ
countersunk installation: 0,002 W/K
surface fixed installation: 0,002 W/K
Use categories acc. to ETA*: A, B, C, D, E
German DIBt approval: Z-21.2-1769
European Technical Approval: ETA-04/0023
Values in parentheses: anchoring in aerated concrete (use category E)
*Specification according to ÖNORM B 6124 for concrete, solid brick and vertical brick
Characteristic loads:
Building material class A:
Normal weight concrete C 12/15 acc. to EN 206-1: 1.5 kN
Normal weight concrete C 16/20 - C 50/60 acc. to EN 206-1: 1.5 kN
Pre-cast concrete panel C16/20 - C50/60: 1.5 kN
Building material class B:
Clay bricks (Mz) acc. to DIN 105: 1.5 kN
Solid lime sandstone (KS) acc. to DIN EN 106: 1.5 kN
Solid masonry of lightweight concrete (V) acc. to DIN 18152: 0.6 kN
Building material class C:
Vertically perforated clay bricks (Hlz) acc. to 105: 1.2 kN
Vertical coring reference bricks (Hlz) acc. to ÖNORM B 6124: 0.75 kN
Sand-lime perforated (KSL) acc. to EN 106: 1.5 kN
Lightweight concrete hollow blocks (HbL)acc. to DIN 18151: 0.6 kN
Baustoffklasse D:
Lightweight aggregate concrete (LAC): 0.9 kN
Building material class E:
Autoclaved aerated concrete P2 - P7: 0.75 kN
For calculation of design loads the national safety factors have to be included (e.g. Germany: 3). Please observe the approval.
More information on : www.ejot.de
Applications :
For surface fixed installation of ejotherm STR U 2G and ejotherm STR U: ejotherm STR bit TX30-M8 x 52
For countersunk installation of ejotherm STR H: ejotherm STR bit TX25-M8 x 31
More information on : www.ejot.de
Applications :
Specially developed tool for countersunk installation of ejotherm STR U 2G according to the EJOT STR principle Also compatible for use with ejotherm STR U und ejotherm STR H and STR H A2 For reliable and easy Installation according to the EJOT STR principle For all insulation boards
Properties :
Adjustment shaft with hex shank for easy use with standard drills Patented mechanism enables quick and easy adjustment to the required anchor length Easy conversion from ejotherm STR tool 2GS for surface fixed installation Robust design for long service life Worn parts can be changed quickly Set contains: ejotherm STR-tool 2GS, additional cutting discs, offset screw driver as well as bits for all applications
More information on : www.ejot.de
Applications :
Ceiling insulation anchor
For fastening of ceiling and acoustic insulation
Recommended substrate: Concrete
Properties :
Easy installation: drill, hammer, done!
Available in colours beige or white
Technical specifications :
Head diameter: 25 mm
Drill hole Diameter: 8 mm
Drill hole depth h1 &ge:; 35 mm
Embedment depth hef &ge:; 25 mm
Recommended substrate: Concrete
More information on : www.ejot.de
Applications :
Fastening ceiling and acoustic insulation boards to concrete substrates
Properties :
Steel screw with self-drilling thread for a secure fastening
Easy installation
Short embedment depth
Plastic injection moulded head with wood wool structure available in beige or white
Can be used in conjunction with the DDT 70 washer for load spreading
Technical specifications :
Head diameter incl. plastic injection moulding:25 mm
Drill hole diameter 6 mm
Embedment depth in concrete: 20 mm
Screw drive: TORX T30
Recommended substrate Concrete
More information on : www.ejot.de
Applications :
Ceiling insulation screw
For a secure fastening of ceiling and acoustic boards
With German DIBt approval
Recommended substrate: Concrete
Properties :
For installation in cracked and non-cracked concrete
Steel screw with duplex coating and self-tapping thread for reliable fastening
Corrosion resistance classification C1-C3
Easy installation: drill, fasten, done
Minimal embedment depth
Standard screw head colour: white
Special service: coloured lacquering of the fastener heads
Technical specifications :
Head diameter: 24 mm
Drill hole diameter: 6 mm
Drill hole depth h1 ≥: 35mm
Embedment depth hef≥: 25 mm
Screw drive: TORX T-30
Recommended substrate: Concrete
Building material class: A2
Corrosion resistance classification: C1 - C3
DIBt approval: Z-21.8-1980
Characteristic load:
Cracked and uncracked normal weight concrete C 20/25 - C 50/60 NRK<7sub>: 0.9 kN
*For further technical specification, please refer to the relevant technical data sheet.
More information on : www.ejot.de
Applications :
Used in conjunction with the DDS anchor for ridgid insulation boards to spread the load
Properties :
Galvanised steel washer
Technical specifications :
70mm diameter
8mm inner diameter
More information on : www.ejot.de
Anwendungen :
Verstellschaft SDS-plus
Alternativer Verstellschaft mit SDS-plus Aufnahme für ejotherm STR-tool 2GS
Weitere Informationen unter: www.ejot.de
Applications :
For fastening External Thermal Insulation Composite Systems with problematic substrates
To combine with EJOT SDF-S plus 8UB
Available in two lengths
With European Technical Assessment
For surface fixed installation
Can be combined with additional washers EJOT SBL 140 plus and EJOT VT 90
Washer diameter: 60 mm
Special sealing plug made of polystyrene (EPS) included in the scope of supply
Technical specifications :
Shaft length EJOT TE 60/50: 50 mm
Shaft length EJOT TE 60/110: 110 mm
Washer Diameter: 60 mm
Screw drive: TORX T30
Drill hole depth h1: ≥ 80 mm
Embedment depth hef: ≥ 70 mm
Point thermal transmission Χ EJOT TE 60/50 with insulation thicknesses 60 - 180 mm: 0.002 W/K
Point thermal transmission Χ EJOT TE 60/110 with insulation thicknesses 120 - 150 mm: 0.00 W/K
Point thermal transmission Χ EJOT TE 60/110 with insulation thicknesses 150 - 240 mm: 0.001 W/K
European Technical Assessment: ETA-04/0064
More information on : www.ejot.de
Applications :
Fastening of External Thermal Insulation Systems on problematic substrates
To combine with EJOT SDF-S plus 8UB
Technical specifications :
Technical data EJOT TE 60/50 and 60/110 in combinaton with EJOT SDF-S plus 8UB
Shaft length EJOT TE 60/50: 50 mm
Shaft length EJOT TE 60/110: 110 mm
Washer diameter: 60 mm
Screw drive: TORX T30
Drill hole depth h1 ≥ : 80 mm
Embedment depth hef ≥ : 70 mm
Point thermal transmission χ TE 60/50: 0.002 W/K
Point thermal transmission χ TE 60/110 with insulation thickness 120-150 mm: 0.000 W/K
Point thermal transmission χ TE 60/110 with insulation thickness 150-240: 0.001 W/K
European Technical Approval ETA-04/0064
More information on : www.ejot.de
Applications :
Brick slip system anchor for aerated concrete
For aerated concrete (E)
Anchor tube with small countersunk head for unobtrusive installation in the joint
Properties :
Approved for aerated concrete (E)
Anchor tube with small countersunk head for unobtrusive installation in the joint
Distort-proof anchor tube
Special expansion zone with hooks for form-fit anchoring
High loads
Premounted screw for quick installation
German DIBt approval: Z-21.2-967
Technical specifications :
Anchor diameter: 8 mm
Diameter of countersunk head: 12 mm
Drill hole depth h1 ≥: 120 mm
Embedment depth hef≥: 110 mm
Screw drive: TORX T30
German DIBt approval: Z-21.2-967
Design loads:
Building material class E:
Autoclaved aerated concrete acc. DIN (2 and 3,3 resp.): 0.2 kN
Autoclaved aerated concrete acc. DIN (4 and 4,4 resp.): 0.5 kN
Autoclaved aerated concrete acc. TGL (Laußig plant): 0.3 kN
Autoclaved aerated concrete acc. DIN TGL (Parchim plant): 0.5 kN
The design loads given are in accordance with the German building code. National safety factors are already incorporated. Please observe the approval.
More information on : www.ejot.de
Anwendungen :
Verblend-Sanierdübel mit verzinkter Stahlschraube für zweischaliges Mauerwerk
Für die nächträgliche Sanierung der Vormauerschale bei Objekten in Industrieatmosphäre und in Meeresnähe
Kostengünstige Wiederherstellung der Standsicherheit
Für Beton, Voll- und Lochsteine (A, B, C)
Mit allgemeiner bauaufsichtlicher Zulassung
Hinweis: Nach der Sanierung der Vormauerschale muss zusätzlich ein Fassadensystem mit einer Wärmedämmung (z. B. WDVS) in einer Dicke von mindestens 60 mm aufgebracht werden. Zusätzlich ist darauf zu achten, dass keine Belüftung hinter der Vormauerschale vorhanden ist.
Eigenschaften :
Bauaufsichtlich zugelassender Dübel zur Sanierung von zweischaligem Mauerwerk
Universalspreizzone: sichere Verankerung in Tragschalen aus Beton, Voll- und Lochsteinmauerwerk
Doppelspreizdübel: verandkert gleichzeitig in tragender Wand und Vormauerschale
Saubere und schnelle Verarbeitung (kein Mörtel notwendig)
100% Setzkontrolle
Temperaturunabhängige Montagezeiten
Verarbeitung bereits ab 0°C
Technische Daten :
Kennwerte:
Bohrlochtiefe h1≥: 80 mm
Bohrlochdurchmesser: 8 mm
Verankerungstiefe hef≥: 70 mm
Schraubantrieb: TORX T25
DIBt-Zulassung: Z-21.2-1652
Zulässige Lasten:
Baustoffklasse A:
Normalbeton ≥ C 12/15 nach EN 206-1: 1,0 kN
Baustoffklasse B:
Mauerziegel (Mz) nach DIN 105: 0,4 kN
Kalksandvollstein (KS) nach DIN EN 106: 0,4 kN
Vollsteine aus Leichtbeton (V) nach DIN 18152: 0,2 kN
Baustoffklasse C:
Hochlochziegel (Hlz) nach DIN 105: 0,25 kN*
Kalksandlochstein (KSL) nach DIN EN 106: 0,25 kN
Hohlblock aus Leichtbeton (HbL) nach DIN 18151: 0,15 kN
* Die angegebenen zulässigen Lasten entsprechen geltenden deutschen Bauvorschriften. Nationale Sicherheitsfaktoren sind bereits berücksichtigt. Bitte Zulassung beachten.
Weitere Informationen unter: www.ejot.de
Anwendungen :
Zur Befestigung von außenseitigen Wärmedämm- Verbundsysteme mit Putzschicht
Zur Befestigung von Brandriegeln
Für die Verankerung in allen Untergründen (A, B, C, D, E)
Für alle Dämmstoffplatten
Für die oberflächenbündige Montage
Eigenschaften :
Zugelassen für alle Baustoffklassen (A, B, C, D, E)
Duale Spreizzone (25/45 mm) für optimalen Halt auch in kritische Untergründe
Axial verschiebbarer Dübelteller für optimales Setzverhalten (Tellereinzug)
Reduzierung von Wärmebrücken durch variablen Unterkopfbereich und kunststoffumspritzten Stahlnagel (0,001 W/K)
Schlanker Dübelteller mit hoher Tellersteifigkeit
Vormontiert für eine schnelle Montage
Mit Zusatztteller montierbar
Technische Daten :
Dübeldurchmesser: 8 mm
Tellerdurchmesser: 60 mm
Bohrlochtiefe h1: ≥ 35 mm (55 mm)
Verankerungstiefe hef: ≥ 25 mm (45 mm)
Punktbezogener Wärmedurchgangskoeffizient λ: 0,001 W/K
Nutzungskategorien ETA*: A, B, C, D, E
Werte in Klammern: Verankerung in haufwerksporigen Leichtbeton und Porenbeton (Nutzungskategorie D, E) *Geeignet gemäß ÖNorm B 6124 für Beton und Vollstein
Weitere Informationen unter: www.ejot.de
Applications :
Specifically matched combination washer for ejotherm STR U 2G for countersunk installation into all mineral wool insulation boards WAP-zg (type WV)
ejotherm VT 2G continues to promote the countersunk installation acc. to STR principle in all mineral wool insulation boards with a low tensil strength WAP-zg (type WV)
For homogeneous surfaces and even rendering
With European Technical Approval (ETA)
Properties :
Low point thermal transmission (Chi value 0.001 W/K)
Reduced anchor marks
No additional tool required
Permanent contact pressure
Anchor locates easily in the washer with a firm "click"
100% setting control
Technical specifications :
Washer diameter: 110 mm
German DIBt approval: Z-21.2-1769
European Technical Approval: ETA-04-0023
The quantity of anchors can be found in the mineral wool approvals for washers ≥90 mm..
More information on : www.ejot.de